Input Voltage
|
115VAC, 60Hz - 400Hz
230VAC, 50Hz single phase
Other inputs available, please consult factory
|
Input Protection
|
Termal fuse / Inrush current limiting
|
Input Isolation
|
2250VDC input to chassis / 4300 VDC input to outpu
2250VDC output to chassis
|
Output Voltage
|
115Vrms / 60Hz / 3-phase
115Vrms / 400Hz / 3-phase
230Vrms / 50Hz / 3-phase are standard
Consult factory for other outputs
|
Wave Form
|
Sinusoidal
|
Total Harmonic Distortion
|
Less than 3% at full load
|
Efciency
|
Min 78% at full load
|
Line Regulation
|
Maximum 0.5%
|
Load Regulation
|
Maximum ± 6% from 1 load to full load
|
Output Protection
|
Current limiting with short circuit protection.
Termal shutdown with automatic recovery
in case of insufcient air?ow
|
EMI
|
Meets EN 55022 Class B
|
Load Crest Factor
|
Maximum 3.0 at 9 load
|
Frequency Stability
|
± 0.1%
|
Operating Temperature Range
|
0o C to +50o C
Extended range available (Consult factory)
|
Humidity
|
5 - 95% non-condensing
|
Temperature Drif
(for level of output V)
|
0.05% per o C over operating temperature range
|
Dimensions
|
4U x 19” x 15” enclosed case
|
Connections
|
Input: Terminal block or studs
Output: Terminal block
|
Weight
|
32 pounds (14.5kg)
|